Reliance Controls TRC1006D Panel/Link Generator Transfer Switch for Up to 15,000-Watt Generators, 12-Circuit 100 Amp Utility/60 Amp Product Description:
- Panel link generator transfer switch
- Interlinked circuit breakers, isolating generator utility
- Can be used as a main panel; 60 to 100 ampere utility subpanel for use with 15, 000-watt generators
- UL listed for outdoor use; heavy-duty, 20 ampere cord
- 5-year limited warranty
Product Description
For generators up to 15,000 Watts and utility input of 100 Amps, this panel can be used as a smaller main panel for a home or cabin, or as a subpanel for a larger building. Interlinked circuit breakers keep the generator isolated from the utility at all times. Accommodates 12 to 20 common circuit breakers to control a variety of appliances and devices. Heavy-duty steel cabinet with steel door covering circuit breakers. Indoor surface or flush-mount design. UL listed. 5-year limited warranty. U.S.A. Factory shipped. Watts: 15,000, Circuits (qty.): 12-20, Amps: 60-100, UL Listed: Yes
Customer Reviews
Most helpful customer reviews
22 of 23 people found the following review helpful.
Good Panel - not cramped - easy install
By Joseph Duclos
I bought this due to the big ice storm we had DEC08. I had originally run my furnace, refridgerator and freezer with extension cords. I decided the next time I wanted a plug and go type affair. I also needed more circuits in my house as the main panel was full. This panel fit my needs nicely.This panel is made by Siemens - very handy as my main panel is also made by them, this means all I had to do was swap breakers from one panel to another, and run the hot wires over with a pigtail extension. Home Depot carries the breakers btw if you need to add some (Murray-MP,C-H BR). I bought 8/3 wire at appx $2 per foot and already had the 12ga and wire nuts for the pigtails.It took 2 days at about 3 hrs per day with a 2yr old and 6 yr old 'helping'.IF YOU DON'T KNOW (not think you know) WIRING - HIRE AN ELECTRICAN. Installing this system exposes you to open buss bars that carry hundreds of Amps - DEATH, QUICK AND CERTAIN if you touch them wrong.If you have installed additonal circuits in your home and put breakers in a panel you should be fine - But please, BE CAREFUL.
6 of 8 people found the following review helpful.
Well made panel
By Chuck Lentz
This panel is very well made,easy to install(with some elctrical knowledge). The switch is very well disigned,has two nuetral bars and a seperate ground bar. Very good investment.
1 of 1 people found the following review helpful.
Worked OK but switch over be warned
By William A
The panel work OK. I was a little disappointed in the switch over breakers. You still need to be careful because both breakers can be engaged at the same time! Luckily my breakers on the gen popped or i would have bucked power and lost the gen. Installation like any panel install it takes time to do right so this took me a week at 4 hours a day. I already had 2 sub-panel and some feeds at each sub needed to be brought over. I'm a little picky about grounding and neutrals as this can hurt your generators load. I was very careful to balance the load on each leg to about 5% delta. Really need to do something about the switch over but for the money worked well.
Latest Price: See on Amazon.com!
More Info: See on Amazon.com!
See Customers Review: See on Amazon.com!